Aquabar.gif (1703 bytes)

LAMsmall.GIF (1292 bytes) Logo.gif (1887 bytes)

HOW TO APPLY

  1. LAM may be applied using one of several application methods, such as sprayer, roller, broom, squeegee, etc. For thick membrane coatings, LAM can be pumped or poured onto a surface, directly from container, then evenly distributed with broom of squeegee. LAM's coverage rate, per square foot, depends on thickness of application.

  2. Estimated Coverage per Thickness:
    Divide thickness in inches into 1.6 for square feet of coverage per gallon. Some examples:
    1/2" thick 3.2 SF per gallon
    1/4" thick 6.4 SF per gallon
    1/16" thick 25.6 SF per gallon
    1/32" thick 51.2 SF per gallon
    1/64" thick 102.8 SF per gallon
    1/300" thick 408 SF per gallon

  3. Precautions:
    Incidental contact with LAM is not hazardous; special clothing is not needed. Avoid contact with eyes and around eye membrane areas. If eye contact is made, rinse with clean running water for 15 minutes or more. Should irritation develop, seek medical attention. If ingested in volumes larger than spray droplets, drink plenty of water and then induce vomiting. If nausea develops, seek medical attention.

[Home]  [Products]  [Successes]  [Search]  [Register]  [About us]  [Site map]

[For Distributors]

3Successes.GIF (514 bytes)

4TechData.gif (648 bytes)

5TheDensifierProducts.GIF (2968 bytes)

6LAMOtherProducts.GIF (1929 bytes)

 

Copyright © 2004 Applied Concrete Technology, Inc. All rights reserved.

Manufacturer:
Applied Concrete Technology, Inc.
Post Office Box 548        
Grayslake, IL 60030
(800) 228-6694 or (847) 548-2444
fax (847) 548-2555